INTRODUCTION
In 1889, Nernst proposed an equation which states that the electrochemical cell potential is directly proportional to the concentration of the sample solution. In 1906, Cremer explained that the potential difference exists between the reference electrode and the indicator electrode. In 1909, pH electrode is developed for the measurement of the potential. Potentiometry is mainly used to determine the potential or the electromotive force of a sample solution. The potential is directly proportional to the concentration of the ions. The potential difference is determined by the electrochemical cell which is composed of pair of electrodes namely the indicator electrode and the reference electrode.
PRINCIPLE
The principle involved in the potentiometry is when the pair of electrodes is placed in the sample solution it shows the potential difference by the addition of the titrant or by the change in the concentration of the ions. This can be seen below:
Reference electrode/salt bridge/analyte solution/indicator electrode Potentiometer
Reference electrode/salt bridge/analyte solution/indicator electrode Potentiometer
The reference electrode is the electrode which consists of its own potential value and it is stable when dipped into the sample solution.
The salt bridge is used to prevent the interference of the analyte solution with the reference solution.
Analyte solution is the sample solution whose potential is to be measured.
The indicator electrode is the electrode which responds to the changes in the potential of the analyte solution.
The electromotive force of the complete cell is given by the following equation:
Ecell = Ereference + Eindicator + Ejunction
where Ereference is the electromotive force of the reference electrode; Eindicator is the electromotive force of the indicator electrode; Ejunction is the electromotive force at the junction of the liquid.
The units for the potential are mille volts denoted by mV.
THEORY
The main theory involved in the potentiometry is when the known potential electrode immersed in the sample solution then the potential is given by the Nernst equation:
E = E0 + (0.592/n) log c
where E is the potential of the solution; E0 is the standard electrode potential; n is the valency of the ions; c is the concentration of the sample solution; 0.0592 is the value obtained from the RT/F, where R is the gas constant, T is the temperature in Kelvin, F is the Faraday's constant.
This can be achieved by the charge transfer process by the following steps:
  • Electrons move from the reference electrode to the indicator electrode.
  • The positive ions move to the cathode and negative ions move to the anode
  • On the surface of the electrodes, electrons are transferred to ions.
A Image A+n + ne
B+n + ne Image B

Factors Affecting Nernst Equation:

  1. Temperature dependent.
  2. Presence of additional potentials.
ELECTRODES
Electrodes are mainly used to measure the voltages. Mainly two electrodes are used in the potentiometry. They are as follows:
  1. Reference electrodes.
  2. Indicator electrodes.
    • Reference electrodes: These are mainly used for the determination of the analyte by maintaining the fixed potential.
    •  Examples:
  • Standard hydrogen electrode.
  • Silver–silver chloride electrode.
  • Saturated calomel electrode.
  • Among these silver–silver chloride electrode is frequently used.
  • The reference electrodes are classified into two main classes. They are as follows:
    1. Primary standard electrodes
    2. Example: Standard hydrogen electrode
    3. Secondary standard electrodes
    1.  Examples:
  • Silver–silver chloride electrode
  • Saturated calomel electrode
  • The ideal requirements of the reference electrodes are the following:
    • It should be stable.
    • It should be reversible.
    • It should be reproducible.
    1. Standard hydrogen electrode: This is used as the primary reference electrode. It consists of platinum foil which is coated with the platinum black and immersed in the HCl solution which contains the hydrogen ions. Hydrogen gas is passed over the platinum foil through the side tube. This is used for the entire pH range. The disadvantages of this electrode are the instability due to the presence of oxidizing or reducing agents and purity of the hydrogen.
    2. Standard hydrogen electrode
    3. Standard hydrogen electrode
    4. The reaction is as follows:
    5. 2H+ + 2e Image H2 (g)
    6. Saturated calomel electrode: It consists of porous disc at the base of the electrode which is clogged. Above it the glass tube is filled with the potassium chloride crystals. And above it is filled with the calomel paste which is prepared by grinding of mercury chloride with pure mercury and minute millilitre of the saturated potassium chloride solution. Then pure mercury is placed in the electrode vessel. The advantages are the easy to construct and highly stable.
    7. Saturated calomel electrode
    8. Saturated calomel electrode
    9. The reaction is as follows:
    10. Hg2Cl2 + 2e Image 2Hg(1) + 2Cl
    11. Silver–silver chloride electrode: Same as the saturated calomel electrode where the silver wire is coated with the silver chloride solution, here the wire is dipped in the saturated potassium chloride solution. The cell consists of the following:
    12. Ag/AgCl, KCl
    13. AgCl(s) + e Image Ag(s) + Cl
      • Indicator electrode: Indicator electrode is used to measure the potential of the analyte solution comparing with that of the reference electrode. Its potential is directly proportional to the ion concentration.
      •  Examples:
  • Hydrogen electrode.
  • Glass electrode.
  • Antimony–antimony oxide electrode.
  • There are two classes of indicator electrodes:
    • Metal indicator electrodes
    • Ion-selective electrodes
    1. Metal indicator electrodes: These develop electric potential in response to a redox reaction on the metal surface. Platinum or Au are used as metal indicator electrodes. These are very simple indicator electrodes. The main disadvantage is that they are not very selective. There are mainly three types of the electrodes used in the potentiometry. They are as follows:
      1. First kind electrodes: They are composed of the metal rod immersed in its metal solution. These electrodes respond to the ionic activity of the electrode.
      2. Examples: Silver electrode dipped in the silver nitrate solution:
      3. Ag+ +e Image Ag
      4. Copper electrode dipped in the copper sulphate solution:
      5. Cu+2 + 2e Image Cu
      6. Second kind electrodes: These are composed of the metal wires coated with the salt precipitates. These electrodes respond to the changes in the ionic activity through the formation of the complex.
      1.  Examples:
  • Ag/AgCl/KCl
  • Hg/Hg2Cl2/KCl
  • Third kind electrodes: These electrodes are also known as inert electrodes and redox electrodes. They are composed of inert metal electrode immersed in the redox solution.
  • Example: Pt–H2 electrode
  • Ion-selective indicators: These are composed of ion-selective membrane by which the ion crosses and it creates the imbalance. Then this opposes the further movement of the ion.
    1.  Examples:
  • Glass membrane electrode
  • Antimony–antimony oxide electrode
    1. Glass membrane electrode: This is most commonly used ion-selective electrode. This responds to the change in the concentration of the hydrogen ions. This is composed of glass tube with a thin glass bulb. In which the silver–silver chloride wire is immersed in it. Lower part of the bulb consists of 0.1N of HCl. This overall setup is immersed in the solution whose potential is to be measured.
    2. Glass membrane electrode
    3. Glass membrane electrode
  • Antimony–antimony oxide electrode: It is composed of the antimony rod dipped in the sample solution. When it is exposed to air it forms the antimony oxide. The main advantage is the stability. The main disadvantage is that it cannot be used in the presence of dissolved oxygen or oxidizing agents.
  • Sb + H2O Image SbO+ + 2H+ + 3e
  • POTENTIOMETRIC TITRATIONS
    In potentiometric titrations, the end point is determined by the sudden change in the potential by the addition of the titrant to the sample solution. This is mainly due to the change in the concentration or ions activity in the sample solution. A simple apparatus is required for simple potentiometric titration which is composed of the reference electrode, indicator electrode and a mechanical stirrer.
    The end point is indicated by the rapid change in the potential. To measure the electromotive force of the electrode, system is measured by the potentiometer or by the electronic voltameter.
    Potentiometric titration apparatus
    Potentiometric titration apparatus
    INSTRUMENTS
    There are mainly three types of the instruments employed for potentiometric measurements. They are as follows:
    1. Non-electronic instrument: It is composed of the battery which supplies the current and is attached to the set of dry cells. This setup is connected to the resistor R, voltameter V and the galvanometer G. Then it is dipped in the sample solution and the potential is recorded.
    2. Non-electric potentiometer
    3. Non-electric potentiometer
    4. Electronic instrument: It is composed of electronic amplifier combined with the glass electrode which is commonly known as the pH meter. The tube consists of the cathode C, a plate B and a grid C. The cathode C is initially heated by the source which releases electrons captured by the plate B. Then small current is passed through the plate and the electrons are repelled by the cathode to the plate B. Finally the setup is attached to the potentiometer which reads the potential of the sample solution.
    5. Electric potentiometer
    6. Electric potentiometer
    7. Automatic instrument: This is the commonly used potentiometer for the potentiometric measurements. It consumes less time to complete the titration and produces the accurate results. This is composed of a potentiometer and an amplifier which are immersed in the sample solution to detect the end point.
    8. Automatic potentiometer
    9. Automatic potentiometer

    Types of Potentiometric Titrations

    They are of following types:
    1. Acid–base titrations: This is mainly based on the changes in the concentration of the hydrogen and the hydroxyl ions which is caused by the neutralization. A known amount of the sample which may be acid or base is taken in the beaker and is titrated with its subsequent acid or base. Then immerse the indicator electrode, for example, glass electrode, and the reference electrode, for example, saturated calomel electrode. Then the potential difference is calculated from the following equation:
    2. E = K − 0.0592 pH
    3. where K is the asymmetry potential.
    4. Then the electromotive force values are plotted against the volume of the titrant.
    5. Acid-base titration curve
    6. Acid-base titration curve
    7. Example: Acetic acid is titrated with the ammonium hydroxide
    8. Redox titrations: These titrations are carried out by using the inert electrode. The sample is titrated with the oxidizing or the reducing agent. This oxidizes or reduces the sample solution which causes the potential difference. Then the potential is calculated from the following equation:
    9. E = E0 + 0.0592/n log10 K
    10. where K is the equilibrium constant.
    11. Which is given by the following equation:
    12. E = E0 + 0.0592/n log10 [OX]/[Red]
    13. where [OX] is the concentration of the oxidant; [Red] is the concentration of the reductant.
    14. In this method, the reference electrode used is the saturated calomel electrode or the silver–silver chloride electrode. The indicator electrode used here is the platinum foil or wire. The plot between the e.m.f values and the volume of the titrant shows the following:
    15. Redox titration curve
    16. Redox titration curve
    17. Precipitation titrations: This method is mainly used in the quantitative determination of the metal ions by the precipitating agents. The end point is determined by the following equation:
    18. E = E0 + 0.0592/n log10 [M n +]
    19. where [Mn+] is the concentration of the metal ions.
    20. In this method, the reference electrode used is the saturated calomel electrode or hydrogen electrode and the indicator electrode used is the silver wire electrode.
    21. Complexometric titrations: The complexometric is mainly used to determine the metal ions which are complexated by the complexing agents. For example, ethylene diamine tetra edetate solution which is a popular complexing agent. The reference electrode used in this method is the saturated calomel electrode and the indicator electrode used is the silver electrode.
    22. Example: Silver ions are complexed with the cyanide ions as the titrant solution.
    ADVANTAGES
    • Inexpensive.
    • Interpretation of the values is easy.
    • Applicable for the coloured solutions also.
    • Applicable to the dilute solutions.
    • Broad specificity.
    DISADVANTAGES
    • Calibration of the instrument consumes more time.
    • Interferences of the impurities are more.
    APPLICATIONS
    • Used in the determination of the % of acetyl salicylic acid in aspirin tablets.
    • Used in the determination of the % acetic acid in the vinegar.
    • Used in the determination of the carbonate.
    • Used in the acid base titrations.
    • Used in the precipitation titrations.
    • Used in the complexometric titrations.
    • Used in the biamperometry.
    • Used for the estimation of the saccharin in the food components.
    REVIEW QUESTIONS
    1. What is potentiometry?
    2. What is the principle involved in the potentiometry?
    3. Explain about the theory involved in the potantiometry.
    4. Write about the electrodes used in the potentiometry.
    5. What is the principle involved in the saturated calomel electrode?
    6. Explain the ion-selective electrodes principle.
    7. What is the procedure used in the potentiometry?
    8. What are the different types of instruments used in the potentiometry?
    9. What are the different types of potentiometric titrations?
    10. What are the applications of potentiometry?


    Comments

    Anonymous said…
    baka yaroooooooooooooooooooooooooooooooooooiooooooooooooooooooooooooooooooooooooooooooooooooooooooooooooo
    John Kennedy said…
    This comment has been removed by the author.
    Anonymous said…
    Buy Ketamine Powder Online
    https://discussketamine.com/question/where-to-buy-ketamine-in-california-usa//"rel="dofollow">Buy Ketamine Powder Online
    BuySomawatson said…
    When administered under a healthcare professional's supervision, Soma (carisoprodol) may be helpful for specific medical disorders and circumstances. Muscle tension and spasms are decreased.
    Buy soma 350mg online
    Buy Soma Online USA
    Buy Soma watson
    watson soma
    Buy soma carisoprodol watson 350mg online
    buy soma (carisoprodol) online
    buy soma online usa
    Buy Soma Online
    kalpna said…
    This comment has been removed by the author.

    Popular posts from this blog

    Diazotization Titrations

    Free pharmacy material Diazotization Titrations INTRODUCTION The diazotization titration is nothing but the conversion of the primary aromatic amine to a diazonium compound. This process was first discovered in 1853 and was applied to the synthetic dye industry. The reaction mechanism was first proposed by Peter Griessin. In this method, the primary aromatic amine is reacted with the sodium nitrite in acidic medium to form a diazonium salt. This method is first used in the determination of dyes. PRINCIPLE The principle involved in this method is that the primary aromatic amine present in the sample reacts with the sodium nitrite in the presence of acid such as hydrochloric acid to obtain a diazonium salt. R − NH 2 + NaNO 2 +HCl R − N + ≡ N − Cl − + NaCl + H 2 O Sodium nitrite is added to the solution of amine in the presence of acid at 0–5 °C. The amine reacts with the nitrous acid to form nitrosamine, which is followed by the tautomerisation and the water mol

    Nephelometry and Turbidimetry

    Free pharmacy material Nephelometry and Turbidimetry INTRODUCTION This is mainly used to determine the scattering of the light by the suspended particles present in the sample solution. The instruments used for the measurement of the scattering are called nephelometer and turbidimeters. The choice between the nephelometry and turbidimetry depends upon the fraction of light scattered. This light scattering by the particles which are present in the colloids is known as the Tyndall affect. Nephelometry is the measurement of the scattered light by the suspended particles at right angles to the incident beam. This method is mainly used for the determination of the low concentration suspensions. Turbidimetry is the measurement of the transmitted light by the suspended particles to the incident beam. This is used for the determination of the high concentration suspensions. PRINCIPLE Light scattering is the physical character of the sample which will depend on the following:

    Electrogravimetry

    Free pharmacy material Electrogravimetry INTRODUCTION Luckow first discovered the electrogravimetry for the determination of the copper. Then Alexander Classen first published the paper on the electrogravimetry in 1881. After that, Gibb's was the first founder of the electrogravimetry for the deposition of the metals on the mercury cathode. Electrogravimetry is a method for the separation of the metal ions by using the electrodes. The deposition takes place on the one electrode. The weight of this electrode is determined before and after deposition. This gives the amount of the metal present in the given sample solution. PRINCIPLE The main principle involved in this method is the deposition of the solid on an electrode from the analyte solution. Electrogravimeter The material is deposited by means of potential application. The electrons are transported to electrode by the following mechanisms: Diffusion Migration Convection THEORY A metal